NOVELL TECHNICAL INFORMATION DOCUMENT
TITLE: Fix for Print Job Configuration Limit
DOCUMENT ID: TID014984
DOCUMENT REVISION: A
DATE: 17FEB94
ALERT STATUS: Yellow
INFORMATION TYPE: Symptom Solution
README FOR: PU4X01.EXE
NOVELL PRODUCT and VERSION:
NetWare 4.01
ABSTRACT:
These files provide a fix for the limitation of 60 print job configurations in
a container under NetWare 4.01. Applying all three files is necessary to fix
the problem.
──────────────────────────────────────────────────────────────────────────────
DISCLAIMER
THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. NOVELL
MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION. HOWEVER, THE
INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION ONLY. NOVELL
MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION.
──────────────────────────────────────────────────────────────────────────────
SYMPTOM
User's are unable to create more than 60 print job configurations.
SOLUTION
Replace the current CAPTURE, PRINTCON, and NPRINT utilities with the
4.02 version of the utilities in PU4X01.EXE.
Self-Extracting File Name: PU4X01.EXE Revision: A
Files Included Size Date Time
\
PU4X01.TXT (This File)
NPRINT.EXE 329271 02-10-94 1:22p
CAPTURE.EXE 335959 02-10-94 1:08p
PRINTCON.EXE 452481 02-11-94 5:28p
Installation Instructions:
1. Backup the current PRINTCON.EXE, CAPTURE.EXE, and NPRINT.EXE files
in the SYS:PUBLIC subdirectory.
2. Flag the current files as RW.
3. Copy the new files into the SYS:PUBLIC subdirectory.
Patch History:
PRINTCON.EXE
2-11-94 This file was fixed to properly create more than 60 print job
configurations in the configuration database.
CAPTURE.EXE
2-10-94 This file was fixed to properly reading the database of print
job configurations allowing access to more than 60
configurations.
NPRINT.EXE
2-10-94 This file was fixed to properly read the database of print job
configurations allowing access to more than 60 configurations.